| Test Name: |
EVEROLIMUS, BLOOD, LC/MS |
| Test Code: |
2194120 |
| Alias: |
18883
LAB18098
|
| CPT Code(s): |
80169
|
| Preferred Specimen: |
2 mL whole blood |
| Container: |
EDTA Lavender |
| Minimum Volume: |
1 mL |
| Collection Instructions: |
Allow lavender tube to fill completely. Invert tube 8-10 times after filling to gently mix and prevent clotting. |
| Transport Temperature: |
Refrigerated |
| Stability: |
Room temperature: 7 days
Refrigerated: 14 days Frozen: 30 days |
| Rejection Criteria: |
Gel barrier tubes • Clotted specimens |
| Limitations: |
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes. |
| Additional Information: |
Drug regimens are to be noted on requisition: Time and date of drug administration. Therapeutic range applies to trough specimens drawn just prior to a.m. dose. |
| Schedule: |
Set up: Monday – Saturday Report Available: 2-3 days |
| Method: |
Chromatography/Mass Spectrometry |
| Performing Lab: |
Quest Diagnostics, Wood Dale #18883 |
| Use: |
Updated: 10/03/2025 |
| Reference Ranges: |
Trough: 3.0-8.0 ng/mL for Transplantation
Trough: 5.0-10.0 ng/mL for Oncology/Neurology
Symptoms of toxicity are more likely to occur at trough levels exceeding 12.0 ng/mL |
|
The CPT codes included in this publication are in accordance with Current Procedural Terminology, a publication of the American Medical Association. CPT codes are provided here for the convenience of our clients; however, correct coding often varies from one carrier to another, and HealthLab may bill specific carriers using codes other than those shown. Clients who bill for services should verify the code(s) with the applicable payor to confirm that their use is appropriate in each case.
|
| Test Type: |
|